PH30 Fire Resistant Cable

Category::LPCB Fire Resistant Cable

Views:1098Times

Release Date:2024-01-22

Contact Us

< >

Detailed Introduction

BS Standard LPCB Fire Resistant Cable

Advantage

* Low smoke, no halogen, fire retardant, fire resistant, environmental 

* Low smoke in fire, no halogen which decrease the damage to equipments and humans 

* High retardance to fire, self- extinguishing 

* Long operational life span, equal to structures life span 

* Higher resistance to electromagnetic interferencen 

* Superior earth continity (The bare CPC is placed between two metallic tapes) 

* Enhanced resistance to cable kinks (Subsequently protecting cables performance) 

* Extremely robuast/durable design (Due to increased tape numbers and overlap) 

* Improved data transmission (Due to twisted cores and additional screening)


Product Property: 

* Conductor : Stranded Bare copper, class 1

* Insulation : 200°C silicone

* Binding tape: compound mica

* Drain wire : ≥0.5mm tinned copper

* Shielding : fire foil

* Sheath : 90°C LSZH polyolefin

* Insulation at 250-300°C, oxygen index ≥28%

* Sheath at 250-300°C, oxygen index ≥28%

* Hydracid ≥5mg/g PH value ≥4.3

* Transmittance ≥80%

* Physical mechanical propert: insulation tensile strength ≥5.0 MPa elongation at break ≥200%, sheath tensile strength ≥10.0MPa, elongation at break ≥100%

* Min bend radius: 10 x D, at -15°C Min bend dia ≤12.5mm

* Operating voltage: 300/500v

* Testing voltage: 2000v

* Operating temperature: -20°C + 90°C

* Fire retardance compliant to IEC 60331-21; BS6387-2013

* Fire test alone: 950°C, 180 mins

* Fire test with water: 650°C 15mins,then apply fire and water together 15mins

* Fire test with impact:950°C, 15min/30times

* Fire retardance compliant to BS EN50200-2015 PH30,PH60,PH120

Date Sheet

Basic specification:

Certificate

LPCB approved

Standard

BS 7629-1: 2008

Operating temperature

-40°C to 200°C (ambient temp. 90°C)

Voltage rating

300V / 500V

Min bending radius

6 x Diameter

Packaging

Reel 500m, or customized

Feature

Sunlight resistant; Sequential footage marking every 1 meter

Application

Primary for emergency lighting circuit, fire detection, firealarm, voice alarm, etc.

 

 Available size

Ref. No.

C04-2Cx1.0

C04-2Cx1.5

C04-2Cx2.5

Stranded / solid conductor

Solid

Solid

Solid

Conductor size (mm)

1.13

1.35

1.7

Core NO. x Section (mm2)

2 x 1.00

2 x 1.50

2 x 2.50

DC Resistance 20°C (Max, Ω/KM)

18.1

12.1

7.41

Insulation OD (mm)

2.45 ± 0.1

2.60 ± 0.1

2.90 ± 0.1

Insulation THK (mm)

0.62

0.62

0.62

Insulation color

Brown / blue

Brown / blue

Brown / blue

Outer Sheath OD (mm)

6.60 ± 0.2

7.20 ± 0.2

7.80 ± 0.2

Outer Sheath THK (mm)

0.6

0.7

0.7

Outer Sheath color

Red

Red

Red